Two-minute brief
ISO 15189 requirements explained: video brief
A two-minute brief on the five requirement clauses of ISO 15189:2022 and Annex A for point-of-care testing.
Key takeaways
- ISO 15189 uses clauses 4 to 8, in the same pattern as ISO/IEC 17025.
- Patient information, consent, safety and welfare sit in the general requirements.
- Clause 7 follows a sample from request to report.
- Annex A covers point-of-care testing.
- Accreditation is granted for a defined scope of examinations.
Five clauses built around the patient sample
ISO 15189:2022 is organised in five requirement clauses, 4 to 8, in the same pattern as ISO/IEC 17025:2017 rather than the harmonised structure of the management system standards. Clauses 4 to 7 cover the laboratory, its resources and the path of a sample from request to report, and clause 8 covers the management system that supports them. Annex A adds the requirements for point-of-care testing. This short film walks through that structure.
Clause 4 covers impartiality, confidentiality and requirements regarding patients: their information, consent, safety, welfare and access to the service. In practice that means an impartiality assessment covering ownership, commercial pressure and referral arrangements, confidentiality undertakings for staff, students and contractors, and arrangements for patient information, consent and complaints. Clause 5 sets the structural and governance requirements, including a legal entity and a laboratory director with defined responsibilities.
Resources, process and the management system
Clause 6 covers the resources the laboratory needs: competent personnel, facilities and environmental conditions, equipment, calibration and metrological traceability, reagents and consumables, and externally provided products and services. Clause 7 follows the sample through the pre-examination, examination and post-examination processes, including method verification and validation, measurement uncertainty, reference intervals, ensuring the validity of results, reporting and the handling of complaints and nonconforming work.
Clause 8 sets the management system requirements, and Annexes B and C compare the standard with ISO 9001:2015 and with the 2012 edition. The standard applies to medical laboratories of every size and discipline, from clinical chemistry and haematology to microbiology, histopathology and molecular diagnostics. Accreditation is granted by an accreditation body for a defined scope of examinations and maintained through surveillance and reassessment; the 2022 edition replaced ISO 15189:2012 and ISO 22870:2016.
A health authority licence or an ISO 9001 certificate does not satisfy ISO 15189: the standard adds the technical requirements, from the laboratory director and competence per examination to method verification, measurement uncertainty, reference intervals, internal quality control and external quality assessment. Pre-examination arrangements stay the laboratory's responsibility even when the wards collect the samples, and assessors follow a sample from collection to report.
ISO 15189 at a glance
- Purpose
- Quality and competence in medical laboratories, so that examination results are reliable, timely and safe to use in the care of patients
- Relevant to
- Hospital, independent, reference and public health laboratories in every discipline, and the point-of-care testing they are responsible for
- Edition
- ISO 15189:2022, the fourth edition, which replaced ISO 15189:2012 and ISO 22870:2016; the transition from the 2012 edition ended in December 2025
- Accreditation
- Assessed and granted by an accreditation body for a defined scope of examinations, then maintained through surveillance and reassessment
- Sterling's role
- Consulting with your team, Effivity, training, internal audit and assessment readiness, then Sustain™
- Cost and timing
- Total investment for an ISO 15189 medical laboratory management system depends on the current maturity of your processes, the scope, locations and number of employees. The process typically takes 8 to 14 months
ISO 15189: questions people ask
Is ISO 15189 a certification or an accreditation?
An accreditation. An accreditation body assesses the laboratory's competence for a defined scope of examinations and publishes the scope on its register. Certification bodies certify management systems; they do not accredit medical laboratories, and an "ISO 15189 certificate" from one of them is not accreditation.
What changed in ISO 15189:2022, what happened to ISO 22870, and is the transition over?
The 2022 edition follows the structure of ISO/IEC 17025:2017, with the management system last, and puts more weight on risk management and on the patient. ISO 22870:2016 was withdrawn in December 2022 and its point-of-care testing requirements became Annex A. The three-year transition ended in December 2025: accreditation to the 2012 edition is no longer recognised, and a laboratory still holding 2012-era documentation applies against the 2022 edition.
Which accreditation body should we choose, and will our results be recognised abroad?
Normally the national body, for example PAB (Philippines), NABL (India), UKAS (United Kingdom), EIAC (Dubai), GAC (Gulf states), ANAB or A2LA (United States) or NATA (Australia), provided it is a Global ACI MRA signatory for medical testing. Signatory bodies recognise one another's accreditations as equivalent, except where regulation or law provides otherwise, so check the register and the rules of the regulator or sponsor that will rely on your results. In the United States, A2LA also holds deemed status for CLIA.
We are licensed by the health authority and ISO 9001 certified. Does that satisfy ISO 15189?
No. The licence permits you to operate and the ISO 9001 certificate covers the management system; ISO 15189 adds the technical requirements: the laboratory director, competence per examination, equipment and traceability, method verification, uncertainty, reference intervals, quality control and external quality assessment, reporting and the pre-examination phase. Annex B shows where the two overlap, so an existing system is reused, but clauses 4 to 7 still have to be assessed.
Do we have to take part in external quality assessment?
The standard requires the laboratory to ensure the validity of its examination results through internal quality control and external quality assessment, and accreditation bodies expect a plan covering the scope, with evidence that every return was reviewed and acted on. Where no scheme exists, an alternative interlaboratory comparison is agreed and documented.
Keep exploring
Related to this video
The complete guide
Everything on ISO 15189
Start with the ISO 15189 page, or go straight to the guide you need.
On the ISO 15189 page
- What are the main ISO 15189 requirements?
- How do you get ISO 15189 accredited?
- How much does ISO 15189 accreditation cost?
- How long does ISO 15189 accreditation take?
- Who needs ISO 15189 accreditation?
- How ISO 15189 accreditation supports your laboratory, your clinicians and your patients
- Frequently asked questions about ISO 15189
Often combined with ISO 15189
More videos: Laboratories, inspection and accreditation
- How to implement ISO/IEC 17020Implementation walkthrough · 3 min 14 s
- ISO/IEC 17020 requirements explainedTwo-minute brief · 2 min
- How to implement ISO/IEC 17025Implementation walkthrough · 3 min 24 s
- ISO/IEC 17025 requirements explainedTwo-minute brief · 2 min
- How to implement ISO/IEC 17024Implementation walkthrough · 3 min 15 s
- ISO/IEC 17024 requirements explainedTwo-minute brief · 2 min
- How to implement ISO 17034Implementation walkthrough · 3 min 15 s
- ISO 17034 requirements explainedTwo-minute brief · 2 min
- How to implement ISO/IEC 17043Implementation walkthrough · 3 min 15 s
Talk to a consultant
Plan your ISO 15189 accreditation with confidence.
Tell us your goals, locations and target date. We’ll help you define the scope, timeline and next steps.
hello@sterling-grc.com+1 201 263 4443 (global headquarters) · your nearest office and its number are at the top of this page
What would you like to achieve?
Choose a starting point. The enquiry form takes about a minute.
Book my free discovery callContinue to the enquiry form to share your details. Please do not include passwords, sensitive personal information or confidential files. A Sterling consultant replies within one working day. Privacy notice