ISO/IEC 17025 guide
ISO 17025 gap analysis: what Sterling examines in your laboratory, what you receive and what happens next
Clause by clause: ISO/IEC 17025:2017 requirements: every clause explained →
Sterling's ISO/IEC 17025 gap analysis measures your laboratory against clauses 4 to 8, method by method. This guide explains what is examined and how, the report, action plan and estimate you receive, who takes part, and how the results set up the build.
Key points
- A Sterling ISO/IEC 17025 gap analysis measures your laboratory against clauses 4 to 8 of ISO/IEC 17025:2017, method by method, and delivers a gap report, a prioritised action plan and an estimate of effort and timeline to application.
- It is the first stage of a Sterling engagement. It is neither the free online readiness check nor the accreditation body's document review or pre-assessment.
- Evidence comes from watching tests or calibrations being performed, tracing reported results back to their raw data and reading the files behind each method, not from a questionnaire.
- The technical gaps usually set the calendar: unvalidated methods, missing uncertainty budgets, broken traceability and no proficiency testing history take longest to close.
Readiness check, gap analysis and pre-assessment: three different exercises
The readiness check is Sterling's free online tool that returns a score and first priorities from your own answers. In the gap analysis, Sterling's consultants examine the evidence themselves. The pre-assessment, where offered, is the accreditation body's informal visit before its initial assessment.
| Aspect | Readiness check | Sterling gap analysis | Body's pre-assessment |
|---|---|---|---|
| Who carries it out | Your laboratory, online | Sterling consultants with your technical and quality staff | The accreditation body's assessor |
| When | Before any commitment | At the start of the engagement | After application, where the body offers it |
| What it rests on | Your own answers | Methods, records and practice seen first-hand | What the body reviews and observes on its visit |
| What you get | A score and first priorities | Gap report, action plan, effort and timeline estimate | The body's view of readiness for the initial assessment |
What the gap analysis examines
Findings are organised under the five requirement clauses of ISO/IEC 17025:2017 and then broken down by method, because accreditation is granted for a defined list of tests or calibrations, not for the laboratory as a whole.
Governance and structure (clauses 4 and 5)
Whether risks to impartiality have been identified and acted on; how customer information is kept confidential; and whether the range of laboratory activities you intend to claim is written down and matches what you actually do.
Resources (clause 6)
Competence requirements and authorisations for each person on each method; the environmental conditions the methods need and whether they are monitored; the equipment register, calibration programmes and intermediate checks; the chain of calibration certificates that links each result to the SI; and how providers of calibration, reference materials and proficiency testing are selected and evaluated.
Processes (clause 7)
This is usually the longest part. For each method we look at contract review and any decision rule for statements of conformity, whether a standard method has been verified or a laboratory-developed or modified method validated, sampling where you sample, item handling, technical records, uncertainty evaluation, the monitoring that ensures valid results, proficiency testing, report content, complaints, nonconforming work and control of data in spreadsheets and information systems.
Management system (clause 8)
Whether you intend Option A or Option B, and then document and record control, risks and opportunities, improvement, corrective action, internal audit and management review.
How the evidence is gathered
The approach is an audit, with one addition that management system reviews lack: we watch the work.
- Desk review. You send the draft scope, the method list, the equipment register, a few calibration certificates, any validation files and recent reports.
- Opening meeting. Management confirms the intended scope, who needs the accredited results and any date driving the project.
- Observing tests or calibrations. Analysts perform selected methods as they normally would. We compare what they do with the written method and ask how they know the result is right.
- Tracing results back. We take issued reports and follow each back through the technical record: sample receipt, the analyst, the equipment and its calibration status, the environmental conditions, the raw data and any calculation.
- Sampling of records. Samples are small and deliberate, spread across methods, analysts, shifts and sites, and include the difficult cases: a failed quality control run, a complaint, a retest.
- Closing meeting. Preliminary findings are discussed before the report is written, so nothing in it comes as a surprise.
Findings describe the system and the methods, never individual analysts, so people talk openly about how the bench really works.
What you receive
A gap report, by clause and by method
For each requirement area, the report states what is in place and working, what exists but is incomplete or not followed, and what is missing, with the evidence we saw. A method matrix sets every method in the intended scope against the technical requirements: verification or validation, uncertainty, traceability, competence and authorisation, quality control and proficiency testing.
A prioritised action plan
Every gap becomes an action with an owner, a due date and the resources it needs. The items whose evidence takes longest to accumulate come first: calibrations from accredited providers, validation work, uncertainty budgets and enrolment in proficiency testing rounds, whose dates the provider sets. Decisions only management can take, such as dropping a weak method from the first application or buying a reference standard, are listed separately.
An effort and timeline estimate
The time your technical and quality staff will need, the share of the work Sterling carries under each route, the technical spend to plan for without figures attached, and a realistic month for application. A first accreditation typically takes six to twelve months; the ISO/IEC 17025 timeline guide explains what moves that range, and the cost guide explains what moves the investment.
Who needs to be in the room, and for how long
Times are typical for a single-site laboratory with a focused scope.
| Who | What we cover with them | Typical time |
|---|---|---|
| Top management | Why accreditation, the intended scope, impartiality risks, resources and dates | About an hour, plus the closing meeting |
| Laboratory manager or technical manager | Methods, validation status, uncertainty, quality control, reports | Most of the fieldwork |
| Quality manager or coordinator | Management system, document and record control, complaints, corrective action | Throughout the fieldwork |
| Analysts or calibration technicians | Performing selected methods, recording, handling nonconforming work | 30 to 60 minutes per method observed |
| Equipment or metrology lead | Equipment register, calibration programme, intermediate checks, traceability | About an hour |
| Sample reception and reporting staff | Contract review, item handling, report issue and amendment | About an hour |
Fieldwork length depends mainly on the number of methods in scope and the disciplines they span; each further site adds time. Gap analyses that underestimate the work usually discussed methods in an office instead of watching them at the bench.
What happens next: Design™ or Drive™
Once the plan is agreed, the route is chosen. Both routes follow Sterling OS™ and differ in how much of the build Sterling carries.
- Design™, guided implementation. Your staff do the work with Sterling's templates, workshops and coaching. It suits laboratories with a capable quality manager and time for validation work.
- Drive™, fully managed implementation. Sterling's consultants carry the agreed work alongside your technical managers, who keep ownership of their methods and of the experimental data. It suits a heavy workload or a fixed deadline.
Management system records and plan milestones run in Effivity, included with the engagement at no additional cost; technical records stay in the laboratory's own systems and are linked as evidence. The ISO/IEC 17025 implementation plan follows the project from here.
How Sterling runs the gap analysis
At the bench first, then a plan your laboratory can deliver.
Our expert and experienced consultants read your method files, watch the work and trace results back to raw data, drawing on 8,100+ client engagements in 60+ countries since 2003. We ensure successful accreditation for our clients. Accreditation is granted by the accreditation body you apply to, after its own assessment; Sterling does not accredit.
Book a free discovery callWhat a gap analysis is not
- Not an assessment. There is no grant, no refusal and no schedule of accreditation; only the accreditation body decides, after document review, on-site assessment and witnessing.
- Not the readiness check. The online tool reflects your answers; the gap analysis reflects the evidence.
- Not method validation. It identifies which methods need verification or validation and what is missing; the work itself is covered in the method verification and validation guide.
- Not your internal audit. ISO/IEC 17025 requires your own audits of a running system, set out in the internal audit guide.
- Not a document-writing exercise. It tells you which procedures and records each method genuinely needs; the documentation guide lists what is required.
ISO 17025 gap analysis: questions buyers ask
What should a laboratory prepare before an ISO 17025 gap analysis?
The list of methods you intend to put in scope, the equipment register with calibration certificates, any validation or verification files, uncertainty calculations, proficiency testing results, a few recent reports with their raw data, and the complaint log. Send what exists; files produced for the occasion hide the gaps.
Should every method be in the gap analysis, or only the ones we plan to accredit?
Include every method you might apply for, even the doubtful ones. The method matrix often shows that a smaller first scope reaches application months sooner, with the rest added later as an extension.
We already hold ISO 9001 certification. Do we still need a full gap analysis?
Yes, although the management system part is usually shorter. ISO 9001 does not examine validation, uncertainty, traceability or proficiency testing, which is where most laboratory gaps sit.
Does the gap analysis tell us which accreditation body to use?
It confirms who needs to accept your results and flags anything that affects the choice; the guide to choosing an accreditation body covers Global ACI recognition and how to check a body's status for your scope.
Can our own quality manager do the gap analysis?
Yes, and the ISO/IEC 17025 checklist is a good starting point. The limit is familiarity: people stop noticing the shortcuts in their own methods, and reading a requirement the way an assessor does takes practice.
Does the accreditation body see our gap report?
Only if you choose to share it; the report belongs to your laboratory. The body forms its judgement from its own document review, on-site assessment and witnessing, not from a consultant's report.
More ISO/IEC 17025 guides
Every guide in the ISO/IEC 17025 series is written for one question and links back to the hub for the whole picture.
- ISO/IEC 17025 accreditation process, step by step
- ISO/IEC 17025 accreditation cost: what moves the price
- ISO/IEC 17025 documentation: what you need
- ISO/IEC 17025 for environmental laboratories
- ISO 17025 calibration and traceability
- ISO 17025 for food testing laboratories
- ISO 17025 for forensic laboratories and government laboratories
- ISO 17025 implementation plan
- ISO 17025 for in-house laboratories
- ISO/IEC 17025 internal audit: the technical clauses
- Measurement uncertainty under ISO/IEC 17025: a budget you can defend
- ISO/IEC 17025 requirements explained, clause by clause
Keep exploring
Explore more about ISO/IEC 17025
Watch a video on how to implement ISO 17025 here.
Watch a video on ISO 17025 requirements here.
ISO/IEC 17025 resources
Services for ISO/IEC 17025
Talk to a consultant
Find out, method by method, how far your laboratory is from ISO/IEC 17025 accreditation.
Tell us your goals, locations and target date. We’ll help you define the scope, timeline and next steps.
hello@sterling-grc.com+1 201 263 4443 (global headquarters) · your nearest office and its number are at the top of this page
What would you like to achieve?
Choose a starting point. The enquiry form takes about a minute.
Book my free discovery callContinue to the enquiry form to share your details. Please do not include passwords, sensitive personal information or confidential files. A Sterling consultant replies within one working day. Privacy notice